The PE10BF-C high damage threshold pyroelectric energy sensor is designed for low energies with a 12 mm aperture. It can measure energies from 7 µJ up to 10 mJ. It can operate at repetition rates up to 250 Hz and covers the spectral range from 150 to 3000 nm and 10.6 µm.
- High damage threshold BF absorber with 150-3000 nm & 10.6 µm range
- 7 μJ to 10 mJ pulse energy measurement range
- 5 ms maximum pulse width
- Repetition rates up to 250 Hz See All Features
Software
PE-C Sensors with StarLab
Support for PE-C \ PD10-C sensors with Vega, Nova II, Juno, Juno+, Juno-RS, EA-1, StarLite and StarBright in StarLab application is now available. Follow step-by-step instructions to upgrade the embedded software in the PE-C \ PD10-C sensor with the StarLab application
When working with other meters and interfaces it is not necessary to update the embedded software of the PE-C \ PD10-C.
Note: PE-C \ PD10-C sensors can't be upgraded via EA-1 interface..
Features
Measuring Laser Energy with a Pyroelectric Sensor
In this short “Basics” video, we review in general the use of pyro-electric sensors for measuring laser pulse energies.
Premium Energy Sensors – Even for UV
Meet Ophir’s high performance energy sensors for pulsed UV lasers (and not only for UV…). These sensors are the perfect solution for pulsed lasers at 193 and 248 nm.
Energy Sensor Response & Integration Time
There seems to be a good deal of confusion when it comes to the terms “Response time” and “Integration time” of energy sensors. In this video we will clarify the meaning of these terms, as they apply to Ophir’s pyro-electric “Smart Sensors”.
How to Detect Missing Laser Pulses with a Pyroelectric Sensor
This video will show you how to detect and record any missing pulses in your pulsed laser beam application.
Additional Error with Frequency in a Pyroelectric Sensor
In many laser energy sensor specifications, there is an item called "Additional error with frequency". Learn what that means, and why and when it happens, in this video.
Accessories
Fiber Connector Adapters
Fiber Adapter Mounting Bracket
Damage Threshold Test Plates (BF)
Nova PE-C Adapter
Scope Adapter
PE-C to PE Size Adapter
Beam Splitter Assembly for Pyro
Fixed extension cables for Pyro Energy Sensors
Modular extension cables for Pyro Energy Sensors
Resources
Data Sheets
Pyroelectric Energy Sensors 1µJ to 10mJ Datasheet(157.9 kB, PDF) Absorption and Damage Graph(220.6 kB, PDF) Wavelength and Repetition Rate Chart(178.6 kB, PDF)
Drawings & CAD
PE10-C & PE10BF-C Drawing(121.3 kB, PDF)
Catalogs
Energy Sensors Catalog(4.6 MB, PDF) Laser Power & Energy Measurement and Laser Beam Analysis Catalog(27.5 MB, PDF)
Technical Notes
5 Situations Where Laser Performance Measurement is Necessary Effect of Ambient Conditions on Laser Measurements Oscilloscope Adapter for Ophir Pyroelectric Sensors Can Ophir pyroelectric sensors measure single shot energy or energy at very low repetition rates? How to Properly Select a Laser Power or Energy Sensor
Technical Articles
Ophir Power/Energy Meter Calibration Procedure and Traceability/Error Analysis Laser Measurements in Materials Processing