Page view updated with the selected options.

8-100 W Max Power Convection Cooled Thermopile Sensors

These convection cooled thermopile laser sensors are designed to measure low to medium continuous optical powers up to 100 W and intermittently up to 500 W.  Choose a fan-cooled or water-cooled sensor for higher optical power levels.

Show Filters:
Showing 1 - 20 of 29 Items
View:
L30A-EX-10MM Excimer Laser 8W Air-Cooled Ø26mm Thermal Sensor

L30A-EX-10MM Excimer Laser 8W Air-Cooled Ø26mm Thermal Sensor

  • EX type 150 to 700 nm and 10.6 µm absorber
  • 80 mW to 8 W average power measurement
  • 20 mJ to 30 J pulse energy measurement
10A-P Short Pulse 10W Air-Cooled Ø16mm Thermal Sensor

10A-P Short Pulse 10W Air-Cooled Ø16mm Thermal Sensor

  • P type 0.15-8 µm volume absorber for short pulse lasers
  • 40 mW to 10 W average power measurement
  • 10 mJ to 10 J pulse energy measurement
12A Broadband 12W Air-Cooled Ø16mm Thermal Sensor

12A Broadband 12W Air-Cooled Ø16mm Thermal Sensor

  • Broadband 0.19-20 µm absorber
  • 2 mW to 12 W average power measurement
  • 1 mJ to 30 J pulse energy measurement
2 Products
Compare Description Avail. Price
12A Broadband 12W Air-Cooled Ø16mm Thermal Sensor 7Z02638 Thermal Laser Power Sensor, BB Type, 2 mW to 12 W, Ø16 mm, 0.19-20 µm
$1,826
12A Broadband 12W Air-Cooled Ø16mm Thermal Sensor 7Z02638B Thermal Laser Power Sensor, BB Type, 2 mW to 12 W, Ø16 mm, 0.19-20 µm with 5m cable
$1,938
Viewing 5 of 2 Products | View All 2 Products
12A-P Short Pulse 12W Air-Cooled Ø16mm Thermal Sensor

12A-P Short Pulse 12W Air-Cooled Ø16mm Thermal Sensor

  • P type 0.15-8 µm volume absorber for short pulse lasers
  • 2 mW to 12 W average power measurement
  • 1 mJ to 30 J pulse energy measurement
15(50)A-PF-DIF-18 High Peak Power 15/50W Air-Cooled Ø17.5mm Thermal Sensor with Diffuser

15(50)A-PF-DIF-18 High Peak Power 15/50W Air-Cooled Ø17.5mm Thermal Sensor with Diffuser

  • PF type 240-2200 nm high energy density absorber with diffuser
  • 140 mW to 15 W average power measurement
  • 60 mJ to 200 J pulse energy measurement
30A-P-17 Short Pulse 30W Air-Cooled Ø17mm Thermal Sensor

30A-P-17 Short Pulse 30W Air-Cooled Ø17mm Thermal Sensor

  • P type 0.15-8 µm volume absorber for short pulse lasers
  • 60 mW to 30 W average power measurement
  • 40 mJ to 30 J pulse energy measurement
30A-N-18 YAG Laser 30W Air-Cooled Ø17.5mm Thermal Sensor

30A-N-18 YAG Laser 30W Air-Cooled Ø17.5mm Thermal Sensor

  • N type volume absorber for 532 and 1064 nm YAG lasers
  • 60 mW to 30 W average power measurement
  • 30 mJ to 200 J pulse energy measurement
30(150)A-LP2-18 Long Pulse 30/150W Air-Cooled Ø17.5mm Thermal Sensor

30(150)A-LP2-18 Long Pulse 30/150W Air-Cooled Ø17.5mm Thermal Sensor

  • LP2 type 250 to 2200 nm absorber for long pulse lasers
  • 30 mW to 30 W average power measurement
  • 20 mJ to 300 J pulse energy measurement
30(150)A-SV-17 High Damage Threshold 30/150W Air-Cooled Ø17mm Thermal Sensor

30(150)A-SV-17 High Damage Threshold 30/150W Air-Cooled Ø17mm Thermal Sensor

  • Continuous operation with ultra-short pulses without diffuser
  • Ultra-high damage threshold
  • No water cooling
30(150)A-HE-17 High Pulse Energy 30/150W Air-Cooled Ø17mm Thermal Sensor

30(150)A-HE-17 High Pulse Energy 30/150W Air-Cooled Ø17mm Thermal Sensor

  • He type absorber with high pulse damage threshold
  • 50 mW to 30 W average power measurement
  • 60 mJ to 200 J pulse energy measurement
30(150)A-HE-DIF-17 High Pulse Energy 30/150W Air-Cooled Ø17mm Thermal Sensor with Diffuser

30(150)A-HE-DIF-17 High Pulse Energy 30/150W Air-Cooled Ø17mm Thermal Sensor with Diffuser

  • HE high pulse damage threshold absorber with diffuser
  • 50 mW to 30 W average power measurement
  • 60 mJ to 200 J pulse energy measurement
L40(200)A-EX-50 Excimer Laser 35/200W Air-Cooled Ø50mm Thermal Sensor

L40(200)A-EX-50 Excimer Laser 35/200W Air-Cooled Ø50mm Thermal Sensor

  • EX type 150 to 700 nm and 10.6 µm absorber for excimer lasers
  • 300 mW to 35 W average power measurement
  • 100 mJ to 200 J pulse energy measurement
L40(250)A-LP2-50 Long Pulse 40/250W Air-Cooled Ø50mm Thermal Sensor

L40(250)A-LP2-50 Long Pulse 40/250W Air-Cooled Ø50mm Thermal Sensor

  • LP2 type 250 to 2200 nm absorber for long pulse lasers
  • 300 mW to 40 W average power measurement
  • 100 mJ to 10,000 J pulse energy measurement
L40(500)A-LP2-DIF-35 Long Pulse 40/500W Air-Cooled Ø35mm Thermal Sensor with Diffuser

L40(500)A-LP2-DIF-35 Long Pulse 40/500W Air-Cooled Ø35mm Thermal Sensor with Diffuser

  • LP2 type 440 to 2200 nm absorber for long pulse lasers
  • 300 mW to 40 W average power measurement
  • 100 mJ to 2000 J pulse energy measurement
50A-PF-DIF-18 High Peak Power 50W Air-Cooled Ø17.5mm Thermal Sensor with Diffuser

50A-PF-DIF-18 High Peak Power 50W Air-Cooled Ø17.5mm Thermal Sensor with Diffuser

  • PF type 240-2200 nm high energy density absorber with diffuser
  • 140 mW to 50 W average power measurement
  • 60 mJ to 200 J pulse energy measurement
L50(150)A-PF-35 High Peak Power 50/150W Air-Cooled Ø35mm Thermal Sensor

L50(150)A-PF-35 High Peak Power 50/150W Air-Cooled Ø35mm Thermal Sensor

  • PF type 0.15-20 µm high peak power absorber
  • 100 mW to 50 W average power measurement
  • 50 mJ to 300 J pulse energy measurement
L50(150)A-LP2-35 Long Pulse 50/150W Air-Cooled Ø35mm Thermal Sensor

L50(150)A-LP2-35 Long Pulse 50/150W Air-Cooled Ø35mm Thermal Sensor

  • LP2 type 250 to 2200 nm absorber for long pulse lasers
  • 100 mW to 50 W average power measurement
  • 40 mJ to 3000 J pulse energy measurement
L50(300)A-PF-65 High Peak Power 50/300W Air-Cooled Ø65mm Thermal Sensor

L50(300)A-PF-65 High Peak Power 50/300W Air-Cooled Ø65mm Thermal Sensor

  • PF type 0.15-20 µm high peak power absorber
  • 400 mW to 50 W average power measurement
  • 200 mJ to 300 J pulse energy measurement
L50(300)A-LP2-65 Ø65 mm Aperture 0.2-1000 J Intense Pulsed Light Sensor

L50(300)A-LP2-65 Ø65 mm Aperture 0.2-1000 J Intense Pulsed Light Sensor

  • 250-2200 nm LP2 absorber
  • Window removed for accurate measurement of air coupled IPL sources
  • 0.2 to 1000 J energy measurement range
L100(500)A-PF-120 High Peak Power 100/500W Air-Cooled Ø120mm Thermal Sensor

L100(500)A-PF-120 High Peak Power 100/500W Air-Cooled Ø120mm Thermal Sensor

  • PF type 0.15-20 µm high peak power absorber
  • 1000 mW to 100 W average power measurement
  • 6 to 6000 J pulse energy measurement
Page 1 of 2